Products & Services
Cat 5e
Building Wire (IEC)
Building Wire (Australia)
Power Supply Cords (IEC)
Power Supply Cords (Australia)
Internal Connection (IEC)
Internal Connection (Australia)
Internal Connection (Australia)

SINGLE CORE CABLE 

 
 
 

PVC Insulated no-Sheathed Electrical Cable to AS/NZS 5000.1:2005

 

Application

For use in conduit and fixed, protected installation in switchgear, lighting and appliances.

Conductor

Class 2 stranded plain copper conductors to AS/NZS 1125:2001 Table 2.3

Class 1 solid plan copper conductor to AS/NZS 1125:2001 Table 2.2

Insulation

PVC (Thermoplastic polyvinyl chloride) to AS/NZS 3808:2000 Table 5, PVC compounds for 90℃maximum continuous operating temperature. V-90HT

Insulation Colour

(a) Phase cores red, white (or uncoloured) and blue.

(b) Neutral core black.

(c) Earth core green/yellow.

Voltage Rating

0.6/1kV

Temperature Rating

90℃

Minimum Bending Radius

Up to 10mm2 : 3 × overall diameter         10mm2 to 25mm2: 4 × overall diameter

Nominal area

Conductor Structure

Nominal Thickness of Insulation

Nominal Overall Diameter  mm

Nominal Weight  kg/Km

FRWC

Part Number

Class 1

Class 2

1.5

Earth

1/1.38

7/0.52

0.8

0.6

3.2

2.8

23

20

ABV105

ABV105E

2.5

Earth

1/1.78

7/0.68

0.8

0.7

3.7

3.5

35

33

ABV205

ABV205E

4

1/2.25

7/0.85

1.0

4.7

56

ABV004

6

1/2.76

7/1.04

1.0

5.2

77

ABV006

10

 

7/1.37

1.0

6.2

120

ABV010

16

 

7/1.70

1.0

7.2

181

ABV016

25

 

7/2.14

1.2

9.0

286

ABV025

Above Insulation Thicknesses to AS/NZS 5000.1:2005 TABLE 1



 

SINGLE CORE FLEXIBLE CABLE

 

 
 

PVC Insulated no-Sheathed Electrical Flexible Cable to AS/NZS 3191:2008

 

Application

Designed for use in the switch control, relay and instrumentation panels of power switchgear for purposes such as internal connectors in rectifier equipment, motor starters and controllers

Conductor

Class 5 flexible plain copper conductor to AS/NZS 1125:2001 TABLE 2.4

Nominal Cross Sectional Area

mm2

Conductor Structure

No./mm

Maximum d.c. resistance of conductor at 20℃

Plain annealed copper

ohms/Km

Tinned annealed copper

ohms/Km

0.50

28/0.15

39.0000

40.1000

0.75

42/0.15

26.0000

26.7000

1.00

32/0.20

19.5000

20.0000

1.50

48/0.20

13.3000

13.7000

2.50

49/0.25

7.8900

8.2100

Insulation

PVC (Thermoplastic polyvinyl chloride) to AS/NZS 3808:2000 Table 5, PVC compounds for 90℃maximum continuous operating temperature. Type V-90HT

Insulation Colour

(a) Active cores: brown, black, white or grey, orange.

(b) Neutral core: Light blue

(c) Earth core: green/yellow.

Temperature Rating

90℃

Minimum Bending Radius

6 × overall diameter


Ordinary Duty Flexible Cable

Voltage designation: 250/440 V

Insulation Thickness to AS/NZS 3191:2008 TABLE 2.2

Nominal Cross Sectional Area

mm2

Insulation Thickness

mm

AMP Rating

 

Nominal Overall Diameter

mm

Nominal Weight

 

kg/Km

FRWC Part Number

0.50

0.6

3.0

2.2

9.0

ARV005

0.75

0.6

7.5

2.4

12.0

ARV075

1.00

0.6

10.0

2.6

15.0

ARV100

 

Heavy Duty Flexible Cables

Voltage designation: 0.6/1kV

Insulation Thickness to AS/NZS 3191:2008 TABLE 2.3

Nominal Cross Sectional Area

mm2

Insulation Thickness

mm

AMP Rating

 

Nominal Overall Diameter

mm

Nominal Weight

 

kg/Km

FRWC Part Number

0.50

0.8

3.0

2.6

11.0

AHRV005

0.75

0.8

7.5

2.8

14.0

AHRV075

1.00

0.8

10.0

3.0

17.0

AHRV100

1.50

0.8

15.0

3.3

22.0

AHRV105

2.50

0.9

20.0

3.95

35.0

AHRV205




Single Core Circular Cables

 
 
 

PVC Insulated PVC Sheathed Single Core Circular Cables to AS/NZS 5000.2:2006

 
 

Application

For fixed applications in power and lighting circuits in installations.

Fixed installation in dry or damp areas for domestic and light industrial wiring.

Conductor

Class 2 stranded plain copper conductors to AS/NZS 1125:2001 Table 2.3

Nominal Cross Sectional Area

 

mm2

Number and Diameter of Wires in Conductor

No./mm

Maximum Resistance Conductor at 20℃ Plain Wires

ohms/km

1.50

7/0.50

13.6000

2.50

7/0.67

7.4000

4.00

7/0.85

4.6000

Core Colours

Read, Brown, Black, Light blue

Sheath Colour

White

Insulation

PVC (Thermoplastic polyvinyl chloride) to AS/NZS 3808:2000 Table 5, PVC compounds for 90℃ maximum continuous operating temperature. Type V-90 or V-90HT

Sheath

PVC (Thermoplastic polyvinyl chloride) to AS/NZS 3808:2000 Table 6, PVC compounds for 90℃ maximum continuous operating temperature. Type 5V-90

Voltage Rating

450/750V

Temperature Rating

90℃

Nominal conductor area

Nominal Thickness of Insulation

Nominal Thickness of Sheath

Nominal Overall Diameter

Nominal Weight

FRWC

Part Number

mm2

mm

mm

mm

kg/Km

 

1.50

0.6

0.8

4.4

35

ABVV105

2.50

0.7

0.8

5.2

52

ABVV205

4.00

0.8

0.9

6.1

77

ABVV004

Above Insulation and Sheath Thicknesses to AS/NZS 5000.2:2006 Table 1